SELF-EXPANDING SEALING TAPE FOR WINDOWS/DOORS
WINDOW BAND
WINDOW BAND self-expanding tape for windows/doors protects them from air and heavy rain while maintaining the thermal-acoustic properties over the entire depth.
It is quick to apply, adapts to surfaces and effectively seals cracks between 6 and 15 mm.
WINDOW BAND window/door sealing tape: ultra-fast installation and effective sealing
Videos
The advantage of WINDOW BAND is that it saves a considerable amount of time during assembly.
With just one product it is possible to seal the three layers without the need for additional solutions. The sealing tape adapts to the surface, ensuring air and water tightness by acting as a vapour control membrane.
Compliant with EnEV and RAL requirements, also guarantees a high level of thermal and acoustic insulation.
Documents
Technical data sheets
|
|
---|---|
File BIM.rfa
|
WINDOW BAND
CODE | B
[mm]
|
measures
[mm]
|
L
[m]
|
B
[in]
|
L
[ft]
|
pcs. | |
---|---|---|---|---|---|---|---|
WINDOW56411 | New | 56 | s: 4-9(MF1)/11(MF2) | 16.5 | 2.2 | 54 | 5 |
WINDOW74411 | New | 74 | s: 4-9(MF1)/11(MF2) | 16.5 | 2.9 | 54 | 4 |
WINDOW56618 | New | 56 | s: 6-15(MF1)/18(MF2) | 11.7 | 2.2 | 38 | 5 |
WINDOW74618 | New | 74 | s: 6-15(MF1)/18(MF2) | 11.7 | 2.9 | 38 | 4 |
WINDOW561536 | New | 56 | s: 15-30(MF1)/36(MF2) | 7 | 2.2 | 23 | 5 |
WINDOW741536 | New | 74 | s: 15-30(MF1)/36(MF2) | 7 | 2.9 | 23 | 4 |
Technical Data
Property | Standard | Tested Values | USC Conversion |
---|---|---|---|
Classification (1) | DIN 18542 | BG1 | - |
Airtightness | DIN 18542 | conforme ai requisiti BG1 | - |
Air permeability (α) | EN 12114 | ≤ 0,1 m³/(h·m·daPa⅔) | - |
Tightness in heavy rain | EN 1027 | ≥ 600 Pa | - |
Light and humidity resistance | DIN 18542 | conforme ai requisiti BG1 | - |
Compatibility with adjacent construction materials | DIN 18542 | conforme ai requisiti BG1 | - |
Water vapour transmission (Sd) | DIN 18542 | conforme ai requisiti BG1 | - |
Water vapour resistance factor (μ) | EN ISO 12572 | < 100 | - |
Water vapour resistance factor (μ) | - | lato chiaro: permeabile al vapore, lato scuro: impermeabile al vapore | - |
Reaction to fire | DIN 18542 | conforme ai requisiti BG1 | - |
Reaction to fire | DIN 4102-1 | class B1 | - |
Acoustic insulation of the joint | - | 59 dB | - |
Thermal conductivity (λ) | EN 12667 | ≤ 0,043 W/(m·K) | ≤ 0.025 BTU/(h·ft²·°F) |
Thermal resistance | - | -30 / 90 °C | -22 / 194 °F |
Application temperature | - | ≥ 5 °C | ≥ 41 °F |
Storage temperature (2) | - | 1 / 20 °C | 34 / 68 °F |