1. PRODUCTS
  2. SOUNDPROOFING
  3. SEALING PRODUCTS
  4. PLASTER BAND IN|OUT

SPECIAL HIGH-ADHESION TAPE, CAN BE ALSO PLASTERED

PLASTER BAND IN|OUT

PLASTER BAND IN and PLASTER BAND OUT are high adhesion tapes ideal for application on most surfaces, even at low temperatures. Made of technical fabric, they can be plastered after installation.

Videos

PLASTER BAND IN/OUT: vapour control and airtightness tapes that can be plastered.

PLASTER BAND is available in two versions: PLASTER BAND IN for application inside the envelope, PLASTER BAND OUT for application on the outside of the envelope. Even when applied in tight spaces and corners, the PP liner of these two highly adhesive tapes can be removed without risk of failure.

The pre-cut liner allows for quick and easy installation and an high level of aesthetics due to the possibility of concealing the tape behind claddings or plaster.

Documents

Technical data sheets

PLASTER BAND IN

CODE liner B
[mm]
L
[m]
liner
[in]
B
[in]
L
[ft]
pcs.
PLASTIN1560 15/60 75 25 0.6/2.4 3 82 5
PLASTIN1585 15/85 100 25 0.6/3.3 3.9 82 4
PLASTIN15135 15/135 150 25 0.6/5.3 5.9 82 2
PLASTIN7520 75 75 25 3 3 82 5
PLASTIN10020 100 100 25 3.9 3.9 82 4
PLASTIN15020 150 150 25 5.9 5.9 82 2

PLASTER BAND OUT

CODE liner B
[mm]
L
[m]
liner
[in]
B
[in]
L
[ft]
pcs.
PLASTOUT1560 15/60 75 25 0.6/2.4 3 82 5
PLASTOUT1585 15/85 100 25 0.6/3.3 3.9 82 4
PLASTOUT15135 15/135 150 25 0.6/5.3 5.9 82 2
PLASTOUT15185 15/185 200 25 0.6/7.3 7.9 82 2
PLASTOUT7520 75 75 25 3 3 82 5
PLASTOUT10020 100 100 25 3.9 3.9 82 4
PLASTOUT15020 150 150 25 5.9 5.9 82 2
PLASTOUT20020 200 200 25 7.9 7.9 82 2

Technical Data PLASTER BAND IN

Property Standard Tested Values USC Conversion
Thickness DIN 53855 0,5 mm 19.7 mil
Mass per unit area EN 1848-2 300 g/m² 0.98 oz/ft²
Water vapour transmission (Sd) EN 1931 ca. 10 m ca. 0.35 US perm
Tensile strength MD/CD EN 12311-1 115 / 75 N/50mm 13.13 / 8.57 lbf/in
Elongation at break point MD/CD EN 12311-1 75 / 80 % -
Watertightness EN 13984 W1 -
Tightness in heavy rain EN 1027 ≥ 1050 Pa -
Air permeability EN 1026 ≤ 0,1 m³/(h·m·daPa⅔) -
UV resistance - 3 months -
Reaction to fire EN 13501-1 class E -
Solvents - no -
Emicode procedura di prova GEV EC1 plus -
Thermal resistance - -40 / 80 °C -40 / 176 °F
Application temperature - ≥ 5 °C ≥ 41 °F
Storage temperature (1) - 5 / 25 °C 41 / 77 °F
1. Store the product in a cool, dry place for no more than 24 months.

Technical Data PLASTER BAND OUT

Property Standard Tested Values USC Conversion
Thickness EN 1942 0,7 mm 27.6 mil
Mass per unit area EN 1848-2 360 g/m² 1.18 oz/ft²
Water vapour transmission (Sd) EN 1931 ca. 1 m ca. 3.497 US perm
Tensile strength MD/CD EN 12311-1 290 / 190 N/50mm 33.12 / 21.7 lbf/in
Elongation at break point MD/CD EN 12311-1 75 / 135 % -
Watertightness EN 13984 W1 -
Tightness in heavy rain EN 1027 ≥ 1050 Pa -
Air permeability EN 1026 ≤ 0,1 m³/(h·m·daPa⅔) -
UV resistance - 12 months -
Reaction to fire EN 13501-1 class E -
Solvents - no -
Emicode procedura di prova GEV EC1 plus -
Thermal resistance - -40 / 80 °C -40 / 176 °F
Application temperature - > -10 °C > 14 °F
Storage temperature (1) - 5 / 25 °C 41 / 77 °F
1. Store the product in a cool, dry place for no more than 24 months.

Composition PLASTER BAND IN

SUPPORT 2-layer PP vapour control membrane
GLUE acrylic dispersion without solvents
RELEASE LINER easy-release PP film

Composition PLASTER BAND OUT

SUPPORT breathable 2-layer PP membrane
GLUE acrylic dispersion without solvents
RELEASE LINER easy-release PP film