VAPOUR CONTROL MEMBRANE

VAPOR 225

The VAPOR 225 vapour control membrane is the cost-effective membrane, ensuring high performance and protection against weathering. It is also suitable for installation on uneven and rough supports, which could damage lighter vapour control layers.

VAPOR 225, the most resistant vapour control membrane on the market.

Although the membrane is very thick and resistant, its composition ensures great flexibility in processing without the risk of material wear. The mass per unit area of the membrane provides mechanical strength and protection during construction; VAPOR 225 ranks among the strongest vapour control membranes on the market.

The TT version offers fast installation and professional sealing thanks to the integrated double tape. It is one of the products for which the EPD and LCA environmental declarations have been developed.

Documents

Technical data sheets
Declaration of performance (DOP) Download
Recommendations for installation
Environmental Product Declaration (EPD) Download

VAPOR 225

CODE description tape H
[m]
L
[m]
A
[m²]
H
[ft]
L
[ft]
A
[sft]
pcs./pallet
V225 VAPOR 225 - 1.5 50 75 4' 11'' 164 807 20
VTT225 VAPOR 225 TT TT 1.5 50 75 4' 11'' 164 807 20

Technical Data
EN 13984
L C A L C A
EPD EPD EP D
national-classifications AT Önorm B3667 DB
national-classifications CH SIA 232 V.v.u. V.v.o. H > 90mm
national-classifications DE ZVDH Db
national-classifications FR DTU 31.2 Bs dve E1 Sd3 TR3
national-classifications IT UNI 11470 A/R3

Property Standard Tested Values USC Conversion
Mass per unit area EN 1849-2 225 g/m² 0.74 oz/ft²
Thickness EN 1849-2 0,8 mm 31 mil
Water vapour transmission (Sd) EN 1931 4 m 0.874 PERM
Tensile strength MD/CD EN 12311-2 > 380 / 300 N/50mm > 43 / 34 lb/in
Elongation MD/CD EN 12311-2 60 / 80 % -
Resistance to nail tearing MD/CD EN 12310-1 > 225 / 300 N > 51 / 67 lbf
Watertightness EN 1928 compliant -
Thermal resistance - -20 / 80 °C -4 / 176 °F
Reaction to fire EN 13501-1 class E -
Resistance to penetration of air EN 12114 < 0,02 m³/(m²·h·50Pa) < 0.001 cfm/ft² at 50Pa
Water vapour resistance - after artificial ageing EN 1296 / EN 1931 compliant -
Water vapour resistance - in the presence of alkalis EN 1847 / EN 12311-2 npd -
Thermal conductivity (λ) - 0,3 W/(m·K) 2.08 (BTU·in)/(h·ft²·°F)
Specific heat - 1800 J/(kg·K) -
Density - ca. 250 kg/m³ -
Water vapour resistance factor (μ) - ca. 5000 -
VOC content - 0 % -
UV stability EN 13859-2 3 months -
Exposure to weather - 3 weeks -
Water column ISO 811 > 500 cm > 196.8504 in

Specifications

Supply and installation of vapour barrier screen, type VAPOR 225
CE marking according to : EN 13984

Property:

– Mass per unit area : 225
– Water vapour trasmission (Sd) (m) : 4
– Maximum tensile force MD/CD (N/50mm) : >380/300
– Elongation MD/CD (%) : 60/80
– Resistance to tearing MD/CD (N) : >225/300
– Watertightness (class) : conforme
– VOC emission (COV) (%(class A+)) : 0
– Temperature resistance (°C) : -20/+80
– Reaction to fire (class) : classe E

Indicazioni di posa per: TETTO

VAPOR 225 is placed parallel to the eaves line, starting from the lower edge of the roof. The second layer must be overlapped by at least 10-20 centimetres to the previous one (depending on the slope of the roof), as indicated on the layout according to UNI 11470:2013. The sheet must be applied on a continuous support with a mechanical fastening device. (ex: HAMMER STAPLER, HAND STAPLER o PNEU STAPLER). Once at the top of the roof, it is advisable for the membrane to protrude beyond the ridge line by at least 30 centimetres to ensure a perfect overlap with the strips of sheet that will overlap on the other side of the roof. It is also recommended that the sheets overlap by at least 30 cm even at the end joints. To achieve correct air and water sealing, we recommend the use of ALU BAND, SEAL BAND, EASY BAND, SPEEDY BAND, SOLID BAND, FLEXY BAND, SMART BAND, PLASTER BAND, DOUBLE BAND, SUPRA BAND, BUTYL BAND, MEMBRANE GLUE, SUPERB GLUE, ECO GLUE, FIRE SEALING, FIRE FOAM, FIRE STRIPE, FRONT BAND UV 228.If there is an integrated double adhesive strip, it can replace the correct air and water sealing.

Indicazioni di posa per: PARETE

VAPOR 225 is laid parallel to the dock beam or the floor if laid on a wall. The second layer must be overlapped by at least 15 centimetres. Each layer must be fixed to the substrate with a mechanical fastener. (ex: HAMMER STAPLER, HAND STAPLER o PNEU STAPLER). It is also advisable to overlap the sheets by at least 30 centimetres at the butt joints. In order to achieve correct air and water sealing, we recommend the use of ALU BAND, SEAL BAND, EASY BAND, SPEEDY BAND, SOLID BAND, FLEXY BAND, SMART BAND, PLASTER BAND, DOUBLE BAND, SUPRA BAND, BUTYL BAND, MEMBRANE GLUE, SUPERB GLUE, ECO GLUE, FIRE SEALING, FIRE FOAM, FIRE STRIPE, FRONT BAND UV 228 or in the case of rough surfaces (such as rough OSB) FLEXI BAND, PRIMER SPAY, PRIMER .

Composition

TOP LAYER non-woven PP fabric
middle layer vapour control PP film
BOTTOM LAYER non-woven PP fabric